The electrical part of the QE model meat cutting machine is mainly composed of a contactor, a start button, a stop button (emergency stop), a motor protector, a magnetic switch and the like.

QE meat cutting machine Circuit diagramB8630692

Contactor: Close the contacts to reach the electrical control of the motor.

Start button: using normally open contacts

Stop button: using a normally closed contact

Motor protector: The current value of the motor current reaching the protector is disconnected.

Magnetic switch: The protective cover is removed and the motor cannot be started. Protect personal safety.

 

笔记: Please disconnect the power supply to prevent electric shock.